22297
FC18 function not possible
Siemens · SINUMERIK 828D CNC Control
What does 22297 mean?
This alarm indicates that a function request made by the PLC via the FC18 interface could not be executed. The alarm message includes a specific error code (e.g., 5 for switchover not possible, 23 for MD 30132 IS_VIRTUAL_AX set) that specifies the exact reason for the failure. This prevents NC Start in the affected channel, leading to production halts and potential process inconsistencies if the function is critical.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Verify the machine data setting MD 30132 IS_VIRTUAL_AX if error code 23 is displayed, ensuring it's not incorrectly set for a virtual axis.
- 4
Clear the alarm using the Delete key or NC START.
Source: Siemens SINUMERIK 828D CNC Control