Macro execution not possible
Siemens · SINUMERIK 828D CNC Control
What does 207082 mean?
A macro program could not be executed due to various underlying causes. The fault value (r0949, hexadecimal) provides detailed information, including the preliminary parameter number, supplementary information, and the specific fault cause. This can range from invalid files, incorrect data types, or unauthorized parameter writes, preventing the macro from completing its intended function.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Check all TAG data types, error levels, and modes within the macro for correct definition and ensure no invalid strings are used for parameter values.
- 4
Confirm that the drive object type is correctly specified and that the target device for the macro operation can be found.
- 5
Ensure that the parameter being written to by the macro is permitted to be modified via this method, as some parameters may be write-protected.