SI CU: STOP A initiated
Siemens · SINUMERIK 828D CNC Control
What does 201600 mean?
This fault indicates that the drive-based Safety Integrated (SI) function in the Control Unit (CU) has detected an anomaly and initiated a STOP A, which involves pulse suppression via the safety shutdown path. This can be due to an unsuccessful forced checking procedure of the safety path, or a subsequent response to a monitoring channel defect (F01611). The fault value provides more detail, such as stop requests, pulse suppression issues, or feedback discrepancies. This safety-critical fault immediately inhibits motor operation to prevent hazardous situations.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Replace the involved Motor Module if the issue persists after STO cycle or F01611 diagnostics, indicating a hardware fault.