Spindle Supplementary Temperature Fault
Siemens · SINAMICS S120/S150 List
What does F07018 mean?
This fault is issued immediately if the actual spindle temperature (r4105) exceeds the fault threshold p4102[1]. Alternatively, if the alarm threshold p4102[0] is exceeded and the delay time set in p4103 expires without the temperature falling below the alarm threshold, this fault is also triggered. The fault requires acknowledgment and clears only when the temperature falls below the fault threshold, considering a fixed 2 K hysteresis.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Inspect the spindle cooling system, motor load, and mechanical components for any issues causing excessive heat generation.
- 4
Verify the operation and wiring of the temperature sensor connected at terminals X522.7(+) and X522.8(-).
- 5
Review the delay time set in p4103; adjust it if it's too short for normal temperature fluctuations, but ensure safety.