61429

Measuring axis (rotary axis 1 or 2) not in basic or intended position

Siemens · FC1765DC Controller

What does 61429 mean?

This alarm indicates that a rotary measuring axis is not in its expected basic or intended position during measurement operations. Error codes 'A' and 'B' relate to rotary axis 1 and 2 not being in basic position on the first measurement. Error codes 'C' and 'D' indicate that rotary axis 1 or 2 are not in their intended positions during subsequent measurements. This can cause inaccurate measurements, leading to incorrect machining outcomes and potential scrap parts.

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    Similarly, check parameters _OVR[60 to 62] for rotary axis 1 (error code 'D') to ensure it is in the intended position for subsequent measurements.

Source: Siemens FC1765DC Controller