61429

Measuring axis (rotary axis 1 or 2) not in basic or intended position

Siemens · DAsl Diagnostics and Alarms

What does 61429 mean?

A rotary measuring axis (either axis 1 or 2) is not in its required basic or intended position during a measurement operation. This can occur on the first measurement (Error A or B) or during subsequent measurements when comparing positions (Error C or D). This will lead to inaccurate measurements or prevent the measurement cycle from proceeding correctly.

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    Verify Rotary axis 1 and 2 are in their intended positions for 2nd or 3rd measurements, checking parameters _OVR[60 to 65].

  2. 4

    Manually move the rotary axes to their correct basic or intended positions before restarting the measurement cycle.

Source: Siemens DAsl Diagnostics and Alarms
View Official PDF