F01

Overcurrent

SEW Eurodrive · MOVITRAC 07B System

What does F01 mean?

An immediate switch-off with inhibit occurs due to excessive current at the inverter output. This can indicate a short circuit, incorrect switching while the output stage is inhibited, an oversized motor for the inverter, or a faulty output stage.

Common Causes

  • Short circuit at output
  • Output switching while output stage is inhibited
  • Motor too large for the inverter
  • Faulty output stage

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Eliminate any short circuit at the inverter output

  2. 2

    Ensure output switching only occurs with an inhibited output stage

  3. 3

    Connect a motor with a smaller rated power appropriate for the inverter

  4. 4

    If the fault cannot be reset, contact SEW Service

Browse all codes in this manual (41)
Verified technical data. Last updated: March 2026

Related Faults

Source: SEW Eurodrive MOVITRAC 07B System