82

Output Open Detected

SEW Eurodrive · MOVIFIT SC

What does 82 mean?

This fault signifies that the measured output current for either drive 1 or drive 2 is less than 2% of the unit's nominal current (IN,unit/device) when the respective drive is enabled. This strongly suggests an open circuit in the motor circuit, such as a disconnected or broken motor cable, a faulty motor winding, or an issue with the drive's output stage itself. This condition prevents motor operation and could indicate significant wiring or motor damage, posing a risk of component failure if the unit attempts to drive into an open circuit.

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    Verify that all terminals connecting the motor to the MOVIFIT unit are securely fastened and making good electrical contact.

  2. 4

    If possible, perform an insulation resistance test on the motor and cable to rule out internal winding failures or hidden damage.

Source: SEW Eurodrive MOVIFIT SC