CAN Communication Timeout
SEW Eurodrive · MOVIFIT SC
What does 47 mean?
This fault indicates a timeout in the cyclical communication over the CAN bus, meaning the unit is not receiving expected data from, or sending data to, another device on the CAN network within the specified time window. This can interrupt critical control and data exchange, leading to system halts, unpredictable behavior, or loss of synchronized operation. It's often related to wiring, termination, baud rate, or configuration issues on the bus, and can cause significant process downtime.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Ensure all devices on the CAN bus, including the master controller, are powered on, functional, and actively participating in communication.
- 4
Monitor the CAN bus activity using a diagnostic tool (e.g., a CAN bus analyzer) to identify communication dropouts, conflicts, or bus errors.