26

External Terminal Low Signal

SEW Eurodrive · MOVIFIT SC

What does 26 mean?

This fault is triggered when a low signal is detected on a specific terminal that has been configured for the '/External fault' function, primarily when the MOVIFIT unit operates as an SBUS slave. This indicates an issue with an external device connected to this terminal, signaling a fault condition from that external source. The low signal could be due to wiring issues, a faulty sensor, or an active fault in the connected external equipment, causing the MOVIFIT unit to stop operation.

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    Troubleshoot the external device connected to this terminal for its specific fault condition, verifying it is not erroneously sending a low signal.

  2. 4

    Measure the signal level on the external fault input terminal to confirm it is within the expected range for proper operation.

Source: SEW Eurodrive MOVIFIT SC