-OLF

Motor Overload

Schneider Electric · Altivar Machine ATV340 Programming

What does -OLF mean?

This fault indicates that the connected motor has experienced a prolonged overload condition, causing its estimated thermal state to exceed safe limits (118% as per page 75). This protects the motor windings from overheating and damage. It could be due to incorrect thermal protection settings or an undersized motor for the application, leading to premature motor failure.

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    Allow the motor to cool down completely before attempting to reset the fault and restart operation. Re-evaluate if the motor itself is undersized for the application's continuous load requirements.

Source: Schneider Electric Altivar Machine ATV340 Programming