Ot

Overtorque

Schindler · Altivar 212 Variable Frequency Drive

What does Ot mean?

This fault occurs when the calculated motor torque reaches or exceeds the level set by parameter F616 ([Overtorque level]), indicating that the motor is operating under excessive load and could be damaged.

Common Causes

  • Calculated motor torque has reached the level set by parameter F616.
  • Excessive mechanical load on the motor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Adjust the settings of parameters F615 ([Overtorque det.]) and F616 ([Overtorque level]) as needed.

  2. 2

    Verify the machine operation to identify any mechanical binding or obstructions causing high torque.