>start DCS !

Door Check Sequence Not Operational Yet

Otis · GAA21750AK3 Service Tool

What does >start DCS ! mean?

This blinking event message indicates that the Door Check Sequence (DCS) for the OTIS 2000 Controllers MCS120/MCS220 has not yet been performed or is not fully operational, consequently blocking elevator movement. The DCS is a critical safety verification for hoistway door contacts.

Common Causes

  • The Door Check Sequence has not been initiated since the last power cycle or system setup.
  • The DCS was interrupted or failed to complete successfully.
  • Incorrect configuration settings preventing the DCS from running.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Initiate the Door Check Sequence (DCS) through the GAA21750AK3 service tool menu (SETUP > DCS Run).

  2. 2

    Monitor the DCS progress and address any specific door errors displayed during the sequence.

  3. 3

    Ensure all door safety contacts are correctly installed and wired before starting the DCS.

Browse all codes in this manual (15)
Verified technical data. Last updated: March 2026

Related Faults

Source: Otis GAA21750AK3 Service Tool
Otis Error >start DCS !: Door Check Sequence Not Operational Yet — Troubleshooting Guide | ErrorLib