Failure in Output Stage (IGBT Desaturation)
Omron · SXF Inverter
What does Desat mean?
This fault indicates a desaturation of IGBTs in the output stage, signaling a hard short circuit between phases or phase to earth, or an earth fault. It can also be related to the brake IGBT (up to SX-D4037). If left unresolved, it can lead to severe damage to the drive's power components and connected motor, requiring costly repairs.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Check for water, moisture, or condensation in the motor housing and cable connections.
- 4
Verify that the rating plate data of the motor is correctly entered into the VSD parameters.
- 5
Inspect the brake resistor, brake IGBT, and their associated wiring for damage or malfunction. For larger units (size G and up), ensure PEB cables to the motor are correctly ordered in parallel connections.