Leakage current to ground in PV array or RisoCtlWarn threshold reached
SMA · SUNNY CENTRAL 500CP XT / 630CP XT Solar Inverter
Hva betyr 3601 ?
A leakage current to ground has been detected in the PV array, or the threshold defined in parameter RisoCtlWarn has been reached. This indicates a potential insulation degradation or grounding issue.
Vanlige årsaker
- Poor grounding or equipotential bonding.
- Issues with module wiring or overall system design.
- Parameter RisoCtlWarn set to an inappropriate value.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the grounding and equipotential bonding connections in the PV system.
- 2
Inspect the module wiring and review the system design for potential leakage paths.
- 3
Verify the value set for parameter RisoCtlWarn.