Fac-Bfr/Fac-Srr
AC Grid Frequency Outside Allowable Range
SMA · SUNNY BOY 5000US-8000US Solar Inverter
Hva betyr Fac-Bfr/Fac-Srr ?
The AC grid frequency has exceeded or fallen below the allowable operating range for the Sunny Boy SB50US-80US-IUS094030. The inverter interprets this as a public grid outage and disconnects from the grid to prevent islanding. 'Bfr' and 'Srr' are internal processor messages.
Vanlige årsaker
- AC grid frequency exceeding the allowed upper limit (<fac Max).
- AC grid frequency falling below the allowed lower limit (>fac Min).
- Rapid change in grid frequency.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the condition of the grid at the AC terminal blocks within the Sunny Boy SB50US-80US-IUS094030.
- 2
Inspect the AC disconnect between the Sunny Boy and the grid.