Oversetter...
EarthCurMax-B
BFR-Related Earth Current Exceeds Tolerable Range
SMA · SUNNY BOY 5000US-8000US Solar Inverter
Hva betyr EarthCurMax-B ?
The earth current between the PV+ conductor and ground (GND), monitored by the BFR (Betriebsführungsrechner), has exceeded its acceptable operating range in the Sunny Boy SB50US-80US-IUS094030. This indicates a ground fault in the PV array. The inverter will disconnect from the grid.
Vanlige årsaker
- Ground fault in the PV array detected by the BFR.
- Ground fault current exceeding 1 Amp.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Switch off the external DC disconnect to the Sunny Boy SB50US-80US-IUS094030.
- 2
Switch off the main AC circuit breaker connecting the Sunny Boy to the grid.
- 3
Troubleshoot the PV array to locate and clear the ground fault.
- 4
Manually clear the ground fault error on the user interface display after correction.