Oversetter...
22295

Spindle DBB30 function not possible

Siemens · SINUMERIK 828D

Hva betyr 22295 ?

The function requested by the PLC via the DBB30 interface could not be executed due to a specific underlying error. This fault disables NC Start in the affected channel and sets interface signals. The exact cause is specified by the error code parameter (%3).

Vanlige årsaker

  • PLC program logic error attempting to call a DBB30 function with incorrect arguments (e.g., invalid function ID or data block structure).
  • Time-out of DBB30 communication between PLC and NC due to excessive network traffic or incorrect communication parameters (e.g., Profinet cycle time mismatch).
  • Internal NC processing error during execution of the requested DBB30 function (e.g., insufficient memory, corrupted internal state).
  • DBB30 interface configuration error in NC, preventing proper interpretation of PLC requests (e.g., incorrect data block address mapping).

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    1. Verify the PLC program logic, specifically the DBB30 function call block, ensuring correct function identifiers and data structures are being sent.

  2. 2

    2. Monitor the communication status between the PLC and NC via the DBB30 interface using diagnostic tools (e.g., TIA Portal online diagnostics, NC trace).

  3. 3

    3. Check NC machine data related to DBB30 interface configuration for correct mapping of data blocks (e.g., MD13000 to MD13009 for DBB30 parameters).

  4. 4

    4. Restart the NC system (Power OFF/ON) to clear any transient internal NC processing errors.

  5. 5

    5. Execute the DBB30 function call using a simplified test program from the PLC to isolate the issue to specific parameters or complex logic.

Se alle koder i denne manualen (37)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder