Oversetter...
A30057

Power unit: Line asymmetry

Siemens · SINAMICS G120C Variable Speed Drive

Hva betyr A30057 ?

Frequencies detected on the DC link voltage suggest line asymmetry or the failure of a line or motor phase. If this alarm persists, it will eventually trigger fault F30011 after a specific duration. This condition causes imbalanced currents, increased losses, and premature component wear, and if unresolved, will lead to a drive trip, interrupting operation.

Vanlige årsaker

  • Loss of one phase in the three-phase AC input supply (e.g., blown fuse, open circuit breaker upstream of the drive).
  • Significant voltage imbalance between the input phases (e.g., >5% deviation) due to utility issues or unequal loading on the grid.
  • Faulty or damaged input line reactor, leading to improper current distribution or voltage drop across phases.
  • Loose or corroded connections at the main power input terminals (e.g., L1, L2, L3) of the drive.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Measure the line-to-line voltages (L1-L2, L2-L3, L3-L1) at the drive's input terminals (e.g., X10/X100 terminals) using a multimeter.

  2. 2

    Check all input fuses and circuit breakers upstream of the drive for continuity and proper function.

  3. 3

    Inspect the input wiring for loose connections or damaged conductors at the main terminals.

  4. 4

    Verify the line reactor's inductance and inspect for visible damage or overheating if present in the input circuit.

  5. 5

    Monitor parameter r0025 for incoming line voltage values to confirm stability and balance.

Se alle koder i denne manualen (34)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Siemens SINAMICS G120C Variable Speed Drive