F01
Overcurrent
SEW Eurodrive · MOVITRAC 07B System
Hva betyr F01 ?
An immediate switch-off with inhibit occurs due to excessive current at the inverter output. This can indicate a short circuit, incorrect switching while the output stage is inhibited, an oversized motor for the inverter, or a faulty output stage.
Vanlige årsaker
- Short circuit at output
- Output switching while output stage is inhibited
- Motor too large for the inverter
- Faulty output stage
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Eliminate any short circuit at the inverter output
- 2
Ensure output switching only occurs with an inhibited output stage
- 3
Connect a motor with a smaller rated power appropriate for the inverter
- 4
If the fault cannot be reset, contact SEW Service
Verifisert teknisk data. Sist oppdatert: March 2026