01
Overcurrent in output stage
SEW Eurodrive · MOVIMOT MM..D With AC Motor DRS
Hva betyr 01 ?
An overcurrent condition has been detected in the inverter's output stage, often due to a short circuit. This can occur either within the inverter output itself, the connecting cable to the motor, or the motor windings.
Vanlige årsaker
- Short circuit on inverter output
- Short circuit in the connection between inverter output and motor
- Short circuit in the motor winding
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the connection between the inverter output and the motor for short circuits
- 2
Check the motor winding for short circuits
- 3
Reset the error by switching off the DC 24 V supply voltage
- 4
Reset the error via the control system or dedicated reset function