Oversetter...
11
Thermal overload of output stage or internal unit fault
SEW Eurodrive · MOVIMOT MM..C
Hva betyr 11 ?
This fault indicates excessive temperature within the inverter's output stage or a general internal malfunction of the unit. Common causes include inadequate cooling, high ambient temperatures, or operation under excessive load.
Vanlige årsaker
- Accumulation of heat due to a dirty heat sink.
- Ambient temperature around the unit is too high.
- Lack of proper ventilation preventing heat dissipation.
- Excessive load placed on the drive.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Clean the heat sink of the MOVIMOT® unit.
- 2
Reduce the ambient temperature surrounding the unit.
- 3
Ensure there is adequate space and airflow to prevent heat accumulation.
- 4
Reduce the load on the drive.
- 5
Switch off the 24 VDC supply voltage to reset the fault.
- 6
Issue a reset command via MOVILINK®.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: SEW Eurodrive MOVIMOT MM..C