F14-0
Encoder not connected, defective encoder, defective encoder cable
SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive
Hva betyr F14-0 ?
The encoder or its cable is either not connected correctly, has a short circuit or broken wire, or the encoder unit itself is defective. It may also occur if 2 inverters are connected via X14 and P505 is set to YES, causing SubC 27.
Vanlige årsaker
- Encoder is not physically connected to the device.
- Encoder cable is damaged or has a broken connection.
- The encoder itself is defective and not functioning.
- Incorrect encoder type selected in configuration.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check encoder cable and shield for correct connection, short circuit and broken wire.
Verifisert teknisk data. Sist oppdatert: March 2026