Faulty switching behavior of the low-side driver DO0_M

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

Hva betyr F109-70 ?

A DC 0 V short circuit has been detected at the digital output DO0_M (X82:2) from the low-side driver. This indicates an electrical fault on the output channel.

Vanlige årsaker

  • Low-side driver for digital output DO0_M is not switching correctly.
  • Short circuit or open circuit on DO0_M output.
  • Defective driver component for DO0_M.
  • Incorrect logic level driving the DO0_M transistor.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check wiring at digital output DO0_M (X82:2).