F109-60

Plausibility fault in the incremental encoder connection

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

Hva betyr F109-60 ?

A phase fault has occurred in the incremental or SIN/COS encoder connection. This indicates an issue with the signal integrity from the encoder.

Vanlige årsaker

  • Faulty incremental encoder signal (A, B, Z) or missing pulses.
  • Incorrect wiring of the incremental encoder inputs.
  • Mechanical detent or backlash affecting encoder count.
  • Noise on the incremental encoder lines.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check encoder connection.

  2. 2

    Replace defective encoder.