F109-46
Voltage supply of encoder faulty (A3403 = encoder 1 and A3404 = encoder 2)
SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive
Hva betyr F109-46 ?
The encoder voltage supply (A3403 or A3404) is outside the defined range (min. DC 20 V / max. DC 29 V). This can be caused by an overload in the supply voltage, potentially tripping an internal polyswitch fuse on the DCS..B option.
Vanlige årsaker
- Voltage supply to encoder 1 (A3403) or encoder 2 (A3404) is outside operating range.
- Wiring fault in encoder power supply lines.
- Defective voltage regulator for encoder power.
- Intermittent power loss to the encoder.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check supply voltage of DCS..B option.
Verifisert teknisk data. Sist oppdatert: March 2026