F109-42

Plausibility fault incorrect acceleration

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

Hva betyr F109-42 ?

The current acceleration has exceeded the configured maximum acceleration limit. This indicates a discrepancy between actual motor dynamics and the set parameters, potentially due to incorrect configuration or mechanical issues.

Vanlige årsaker

  • Measured acceleration value exceeds plausible limits.
  • Encoder velocity or position data indicates unrealistic acceleration.
  • Incorrect configuration of acceleration monitoring parameters.
  • Sensor malfunction causing erratic acceleration readings.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the configuration (encoder screen: max. set speed).

  2. 2

    Analyze the speed/acceleration profile using the SCOPE function.