F109-164
Plausibility fault - SSI encoder connection (master mode)
SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive
Hva betyr F109-164 ?
The connected encoder type does not correspond to the configuration for an SSI encoder operating in master mode. This indicates a mismatch in setup.
Vanlige årsaker
- Faulty SSI encoder connection in master mode.
- Incorrect wiring of SSI encoder signals (clock, data).
- Parameter P0205 setting for SSI master mode incorrect.
- SSI encoder data transmission errors or timeout.
- Clock signal issue from the master drive to the SSI encoder.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check encoder connection and cabling.
- 2
Check the connected encoder.
Verifisert teknisk data. Sist oppdatert: March 2026