F109-152
Difference level RS485 driver. Fault Faulty "A" or "DATA" signal
SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive
Hva betyr F109-152 ?
A fault is detected in the RS485 driver, specifically with the 'A' or 'DATA' signal. This is usually caused by no encoder connection or an incorrect encoder type being connected.
Vanlige årsaker
- RS485 communication line issue between driver and controller.
- Faulty 'A' or 'DATA' signal wire integrity.
- Incorrect RS485 configuration or addressing.
- Intermittent connection on the RS485 bus.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check encoder connection.
- 2
Check encoder cabling.