25

EEPROM error

SEW Eurodrive · Drives

Hva betyr 25 ?

An error occurred while accessing the internal EEPROM of the MOVIMOT® inverter, potentially indicating data corruption or a defective memory chip. This can affect stored parameters and operational settings.

Vanlige årsaker

  • Error during read/write access to the internal EEPROM.
  • Defective EEPROM component.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Set parameter P802 to 'Delivery state' (factory defaults) to reset EEPROM contents.

  2. 2

    Reset the error and then re-parameterize the MOVIMOT® inverter with application-specific settings.

  3. 3

    If the error reoccurs after re-parameterization, contact SEW Service.