0C70
INTERBUS data transfer cancelled (MFI)
SEW Eurodrive · Drives
Hva betyr 0C70 ?
The INTERBUS data transfer was cancelled, either because the initialization of the SUPI 3 protocol chip failed or the MFI is defective. This fault code can also be displayed if a reserved DIP switch setting is selected.
Vanlige årsaker
- Initialization of the INTERBUS protocol chip SUPI 3 failed.
- Defective MFI (INTERBUS interface) hardware.
- Invalid or reserved DIP switch setting selected on the MFI.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the DIP switch setting on the MFI for validity and ensure no reserved settings are selected.
- 2
If the fault persists after verifying DIP switch settings, consider installing a new MFI electronic unit.