0BB4
MFI periphery fault history (PF TEN)
SEW Eurodrive · Drives
Hva betyr 0BB4 ?
The MFI signals a periphery fault when a microprocessor reset has been carried out, typically due to EMC problems or defective hardware. This code logs the last 10 periphery faults, indicating intermittent or persistent issues.
Vanlige årsaker
- Microprocessor reset on the MFI due to EMC (Electromagnetic Compatibility) problems.
- Defective hardware on the MFI electronic unit.
- Interrupted or poor wiring/shielding for the MFI.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the wiring and shielding of the MFI for proper installation and integrity.
- 2
Ensure the MFI is switched on and receiving proper power.
- 3
If the fault reoccurs after checking wiring and power, install a new MFI electronic unit.
Verifisert teknisk data. Sist oppdatert: March 2026