09
Startup error
SEW Eurodrive · Drives
Hva betyr 09 ?
A startup error has occurred, indicating that certain additional functions are not permitted in the current configuration. Specifically, additional functions 4, 5, or 12, controlled by DIP switches S2/5 through S2/8, are active but are not allowed.
Vanlige årsaker
- Additional function 4 (DIP switches S2/5-S2/8 configuration) is active but not permitted
- Additional function 5 (DIP switches S2/5-S2/8 configuration) is active but not permitted
- Additional function 12 (DIP switches S2/5-S2/8 configuration) is active but not permitted
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the settings of DIP switches S2/5 to S2/8 on the MOVIMOT inverter
- 2
Verify that additional functions 4, 5, and 12 are disabled if they are not permitted for the current startup mode
Verifisert teknisk data. Sist oppdatert: March 2026