OL2
Motor Overload
Schindler · Altivar 212 Variable Frequency Drive
Hva betyr OL2 ?
This fault indicates a motor overload condition, potentially caused by incorrect motor control settings, a jammed motor, continuous low-speed operation, or excessive load from the Altivar 212 drive.
Vanlige årsaker
- Incorrect setting of [Mot cont. mode sel.] (Pt).
- The motor is jammed or mechanically binding.
- Continuous low-speed operation is performed.
- Excessive mechanical load is applied to the motor.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Select the correct setting for parameter [Mot cont. mode sel.] (Pt).
- 2
Check the mechanical load for any binding or obstructions.
- 3
Adjust parameter OLM ([Motor overload prot]) to the overload level that the motor can withstand during low speed operation.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Schindler Altivar 212 Variable Frequency Drive