Oversetter...
Delivery Port Door

Delivery Port Door Error

Otis · 400 Elevator

Hva betyr Delivery Port Door ?

Indicates that the DMC is reporting a port door error. This usually means the delivery port door is not opening or closing correctly, which can prevent product dispensing and may cause jams.

Vanlige årsaker

  • Delivery port door sticking in a closed position.
  • Connector to the delivery door switch is disconnected.
  • Defective delivery door switch.
  • Damaged Delivery Door Power/Signal harness or Port/Delivery Door harness.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check to make sure the delivery port door is not sticking in a closed position.

  2. 2

    Clean delivery port door slides or replace the port door.

  3. 3

    Check to make sure that the connector to the delivery door switch is connected.

  4. 4

    Reconnect the connector to the switch.

  5. 5

    Check the delivery door switch and replace if defective.

  6. 6

    Check the Delivery Door Power/Signal harness and the Port/Delivery Door harness for damage and replace any found to be defective.

Se alle koder i denne manualen (41)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder