Process Data Object Setting Missing
Omron · NJ/NX-series Machine Automation Controller
Hva betyr 54013781 hex ?
The PDO mapping for CNC instructions is incorrect. This means required Process Data Objects are not properly configured or the instruction is used with an incompatible device.
Vanlige årsaker
- The PDOs that are required for the CNC instruction are not mapped.
- The relevant instruction was executed for a device that does not have an object that supports the instruction.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the PDO mapping configuration for the CNC instructions within the Sysmac Studio project, ensuring all required Process Data Objects are correctly assigned and enabled.
- 2
Check the compatibility of the connected EtherCAT slave device(s) with the specific CNC instructions being utilized, referencing Omron and device manuals.
- 3
Inspect the EtherCAT slave device parameters and settings in Sysmac Studio to ensure they align with the configured PDOs and CNC instruction requirements.
- 4
Verify the EtherCAT network configuration, including slave node addresses and connection status, to ensure proper communication for PDO transfer.