Oversetter...
183A0000

Non-volatile Memory Data Error

Omron · NJ/NX-series Machine Automation Controller

Hva betyr 183A0000 ?

Corrupted data was detected in the non-volatile memory. This error typically occurs if power is interrupted or significant electrical noise is present during critical data saving operations, such as parameter storage or motor identity information.

Vanlige årsaker

  • Power interruption during saving of non-safety parameters
  • Electrical noise during saving of non-safety parameters
  • Power interruption during saving of motor identity information
  • Electrical noise during saving of motor identity information
  • Power interruption during saving of safety parameters
  • Electrical noise during saving of safety parameters

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the stability of the power supply to the Controller, checking for interruptions or sags.

  2. 2

    Check system grounding and shielding to mitigate electrical noise during data saving operations.

Se alle koder i denne manualen (96)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Omron NJ/NX-series Machine Automation Controller