Encoder Data Restoration Error
Omron · NJ/NX-series Machine Automation Controller
Hva betyr 08170000 hex ?
Initialization of internal position data was not processed correctly in Semi-closed Control Mode and Absolute Value Mode. This implies a failure to correctly establish the encoder's initial position, affecting control accuracy.
Vanlige årsaker
- There is insufficient power supply voltage for the encoder.
- Noise is entering on the encoder line.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Inspect all encoder cable connections at both the absolute encoder and the Omron NJ/NX controller for looseness, damage, or incorrect pinout.
- 2
Measure the supply voltage at the absolute encoder input terminals to confirm it meets the encoder manufacturer's specifications.
- 3
Verify the absolute encoder parameters and settings within the Omron NJ/NX controller, including encoder type, resolution, and absolute position initialization method, against the machine's configuration documentation.
- 4
Check for any signs of electrical noise or interference affecting the encoder signal cable, especially in proximity to power cables or inductive loads.