Oversetter...
E37-2

Outdoor Heat Exchanger Thermistor 2 Failure (Tho-R2)

Mitsubishi Electric · R410A Systems

Hva betyr E37-2 ?

The second outdoor heat exchanger thermistor (Tho-R2) is defective. This prevents accurate temperature measurement of a specific section of the outdoor coil, impacting system control and protection.

Vanlige årsaker

  • Outdoor heat exchanger thermistor 2 (Tho-R2) has failed.
  • Wiring to Tho-R2 is broken or shorted.
  • Tho-R2 reading is out of specified limits.
  • Defective Tho-R2 thermistor.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Measure the resistance of thermistor Tho-R2 at its leads — compare to a resistance-temperature chart if available.

  2. 2

    Inspect the connector for Tho-R2 on the outdoor unit PCB — verify it is securely seated and free from corrosion.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Mitsubishi Electric R410A Systems