F832

Startup Denied (No Startup Condition)

Mitsubishi Electric · MELSEC Q-series MELSECNET/H

Hva betyr F832 ?

Startup has been denied because the system is under a condition of "no startup." This often relates to how the data link was previously stopped. If stopped by all station designation, all stations start; otherwise, automatic startup is denied.

Vanlige årsaker

  • Data link stopped by specific station designation, preventing automatic startup for those stations

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    If the data link was stopped by a designation targeting all stations, verify that all stations are starting

  2. 2

    If the data link was stopped by other station designations, manually initiate startup for the affected stations

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026