Error in the range of the encoder.
Lenze · 9300 Series
Hva betyr 162 ?
The traversing range of the absolute encoder has been exceeded. This means the physical travel of the drive has gone beyond the measurement capabilities of the installed encoder.
Vanlige årsaker
- Physical travel of the mechanical system has exceeded the maximum measurement range of the installed absolute encoder (e.g., single-turn limits, multi-turn beyond specified turns).
- Incorrect encoder scaling factor (e.g., Parameter C0301 for pulses per revolution, C0302 for gear ratio) causing misinterpretation of the actual physical position.
- Homing procedure established an incorrect zero point, leading to a calculated position outside the encoder's valid range during normal operation.
- Encoder damage or internal fault causing it to report values outside its specified operational range.
- System mechanics have physically moved beyond the intended safe travel, often due to an unrelated control error or collision.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
1. Verify the specified absolute encoder range (e.g., number of turns for multi-turn) and compare it against the actual mechanical travel of the axis.
- 2
2. Review and correct the encoder scaling parameters (e.g., C0301, C0302) to ensure accurate position calculation.
- 3
3. Re-perform the homing sequence to establish a correct zero position within the encoder's valid operating range.
- 4
4. Monitor the actual encoder raw counts (if available in diagnostics, e.g., P5-07) and physical position to pinpoint where the range is exceeded.
- 5
5. Check the encoder coupling for slippage or damage that could lead to misreporting of actual position relative to the motor shaft.