No reference.
Lenze · 9300 Series
Hva betyr 156 ?
The reference point for the drive is not known. In absolute positioning mode, homing was not performed before the first positioning command, which is essential for establishing a known position.
Vanlige årsaker
- Drive is operating in absolute positioning mode (e.g., Parameter C1210 = 1 for absolute) but has not completed a homing routine.
- The homing procedure was interrupted, failed (e.g., due to limit switch error), or did not successfully establish a valid reference.
- Encoder battery (for multi-turn absolute encoders) is depleted or disconnected, causing loss of position data on power cycle.
- Homing offset parameter (e.g., C1220) is incorrectly configured, leading to an invalid reference point.
- Memory corruption or parameter reset causing the loss of the stored reference point data.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
1. Initiate and complete a homing sequence as defined in the system's operational manual. Monitor homing status (e.g., P5-06 for 'Homing Done' bit).
- 2
2. For absolute encoders with battery backup, check the encoder battery voltage (if a diagnostic parameter exists) and replace if below specification (e.g., 3.0VDC).
- 3
3. Verify the homing mode (e.g., C1211) and homing offset (C1220) parameters are correctly configured for the application.
- 4
4. Cycle power to the drive and re-attempt homing to confirm persistent loss of reference.
- 5
5. Check the encoder cable and connections (e.g., X2 connector) for any intermittent faults that could cause loss of absolute position data.