Oversetter...
STAS2 Flashing
Safety Node B Internal Fault
Kuka · Sunrise Cabinet Med Controller
Hva betyr STAS2 Flashing ?
The STAS2 (Safety node B) Orange LED is flashing at a rate other than 1 Hz (normal) or 10 Hz (boot phase), indicating an internal fault code within Safety Node B. This suggests a problem with the internal logic, communication, or processing of this safety node, potentially affecting safety chain integrity and preventing safe operation.
Vanlige årsaker
- The Safety Node B (STAS2) microcontroller is experiencing an internal fault, indicated by flashing.
- Internal error within the STAS2 safety device.
- The STAS2 safety processor has detected a critical internal failure.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check cabling at connectors X309, X310, and X312 for proper connection, integrity, and any signs of damage.
- 2
For test purposes, disconnect the cables at X309, X310, and X312, then switch the controller off and back on again to reset the module.
- 3
If the error recurs after checking cabling and power cycling, exchange the CCU_SR module.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Kuka Sunrise Cabinet Med Controller