MissingProcess- Gas
No process gas!
Kuka · LaserTech 3.1
Hva betyr MissingProcess- Gas ?
The required process gas supply is either off, depleted, or not reaching the laser system at the required pressure. This prevents proper laser operation and affects process quality.
Vanlige årsaker
- Process gas supply is interrupted or absent.
- Low pressure detected in the process gas line.
- Gas flow sensor failure or blockage.
- Incorrect gas mixture detected.
- Gas cylinder depleted or valve closed.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the process gas supply tank level and ensure all gas valves are open.
- 2
Check the gas pressure at the laser system's input manifold.
- 3
Acknowledge the message on the robot controller HMI.
- 4
Resume or restart the program.