LaserAllocation- Avoided

Laser allocation denied

Kuka · LaserTech 3.1

Hva betyr LaserAllocation- Avoided ?

The system's request to allocate the laser has been denied. This can happen if the laser is already allocated to a different station, is in manual mode, or if another active error prevents allocation.

Vanlige årsaker

  • Request to use a laser source was rejected by the system.
  • Laser resource is currently unavailable or allocated to another task.
  • System logic prevented laser activation due to safety or operational constraints.
  • The intended laser process is not permitted under current conditions.
  • Configuration error preventing laser resource assignment.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify if the laser is currently allocated to a different workstation or process; release if necessary.

  2. 2

    Confirm the laser is not in manual mode (refer to 'LsrInManual-Mode' for resolution).

  3. 3

    Check for other active laser errors that might prevent allocation and resolve them.