Oversetter...
26009

Motor blocked ({Drive})

Kuka · KSS 8.3 System Software

Hva betyr 26009 ?

The motor for the specified drive is blocked, meaning it is unable to move or has encountered significant resistance preventing its commanded motion. This is a regular monitoring function that protects the motor from damage due to excessive force. In torque mode, this monitoring can be automatically deactivated by `SET_TORQUE_LIMITS()` with `monitor #off`.

Vanlige årsaker

  • The motor is experiencing excessive resistance or is physically blocked.
  • Mechanical obstruction preventing the motor from rotating.
  • Overload condition or fault within the drive system preventing motor movement ({Drive}).

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Identify the specific drive mentioned in the error message to locate the affected motor/axis.

  2. 2

    Physically inspect the robot's axis corresponding to the drive for any obstructions, mechanical binding, or foreign objects preventing movement.

  3. 3

    Check for excessive external loads applied to the robot that might be overloading the motor.

  4. 4

    Verify the motor's power supply connections and cabling for proper integrity and voltage.

  5. 5

    If operating in torque mode and this monitoring is not intended, ensure `SET_TORQUE_LIMITS(..., monitor #off)` is correctly configured for the drive.

Se alle koder i denne manualen (6)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder