2858

Stop Due to Field Bus Error

Kuka · KR C4 PROFIBUS

Hva betyr 2858 ?

The robot controller has entered a stop state because an error occurred on the field bus. This indicates a general issue preventing normal operation over the PROFIBUS.

Vanlige årsaker

  • Loss of communication with a critical field bus device (e.g., I/O module, drive).
  • Network congestion or packet loss on the field bus.
  • Incorrect or missing configuration of a field bus node.
  • Physical damage to the field bus cabling or connectors.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the status LED on each field bus node is illuminated green.

  2. 2

    Inspect the field bus cable integrity from the controller to the furthest node.

  3. 3

    Check the field bus termination resistors at both ends of the bus.

  4. 4

    Review the field bus configuration parameters in the controller, specifically the node addresses.

  5. 5

    Measure the signal amplitude on the field bus data lines.