Oversetter...
10039
PROFIBUS Master Error in Module
Kuka · KR C4 PROFIBUS
Hva betyr 10039 ?
The PROFIBUS master encountered an error within a specific module, identified by its name and further detailed by an internal error code. This suggests a component-specific issue on the PROFIBUS master. Refer to the PROFIBUS master's manufacturer documentation for details on the specific error code.
Vanlige årsaker
- The PROFIBUS master detected an internal error within a specific slave module.
- A slave module on the PROFIBUS network returned an invalid response to the master.
- Corrupted data packets originating from or intended for the module.
- The module's firmware is incompatible with the master's protocol version.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Identify the faulty module by its PROFIBUS address from the error message.
- 2
Check the status indicator on the identified PROFIBUS module.
- 3
Disconnect the problematic module from the PROFIBUS network and observe if the error clears.
- 4
Review the PROFIBUS diagnostic logs for detailed information on the module's communication.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Kuka KR C4 PROFIBUS