Communication error, KPP/KSP (axis)
Kuka · KR C4 Operating Instructions
Hva betyr 26114 ?
A communication error has occurred on the controller bus, specifically identified as an EtherCat issue, involving the KPP or KSP device for a specific axis. This indicates a disruption in data exchange between the KPP/KSP and the main controller or other bus participants. Loss of communication can prevent axis control and coordinated motion.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Perform a Power Off / Power On cycle of the entire system to reinitialize the drive bus.
- 2
Inspect all EtherCat cabling for damage, proper connection, and secure latching at all nodes.
- 3
Verify the configuration and operational status of the EtherCat stack within the controller software.
- 4
Check the status indicators and diagnostics of the CCU (Controller Control Unit).
- 5
Check the status indicators or diagnostics of the KPP device.
- 6
Check the status indicators or diagnostics of the KSP device.