invalid Gateway PDO-Config

Invalid Gateway PDO-Config

Kuka · KR C4 DeviceNet

Hva betyr invalid Gateway PDO-Config ?

No valid process data object (PDO) configuration is available for the gateway module. This prevents proper data exchange over DeviceNet and results in a DeviceNet master configuration error (Message 4429).

Vanlige årsaker

  • Invalid configuration detected for the Gateway's PDO (Process Data Object) settings.
  • PDO mapping or size is incorrect for the connected devices.
  • Communication error related to PDO transmission.
  • Incorrect parameter settings for PDO synchronization (P1-250, P1-251).

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the bus configuration for the gateway module and correct it if necessary.

  2. 2

    Reconfigure the bus after verifying the configuration.

Se alle koder i denne manualen (12)
Verifisert teknisk data. Sist oppdatert: March 2026